LUMINO WAVE
Modelo: LSR-10
Dispositivo de Convergencia de Nueva Generación
Utilizando microburbujas inducidas por ultrasonido para mejorar la profundidad de penetración del láser en la piel, LUMINO WAVE representa la próxima evolución en terapia de convergencia. Actualmente en proceso de aprobación MFDS.
Certificaciones
Imágenes del Producto











Tecnologías Clave
Convergencia Ultrasonido + Láser
Terapia de convergencia donde la vibración ultrasónica y la irradiación láser ocurren simultáneamente. La dispersión de la luz se minimiza, permitiendo que el láser alcance capas más profundas.
Time-division control — alternating, never overlapping
Wave and light fire in alternation on a millisecond time base and never overlap. One cycle repeats 50–200 times, with rest gaps after each energy. Timing is clocked on time rather than position, so the sequence holds steady while the handpiece moves.
Three energies, one platform
980nm diode laser for selective photothermal action, 1MHz non-focused planar ultrasound that spreads micro-vibration across the whole contact surface with no focal heating by design, and 2MHz RF for non-invasive deep warmth. All three run in pulse mode at 10–100% intensity.
Indicaciones
These are the applications LUMINO WAVE is being developed for. Korea MFDS approval is in progress and CE-MDR and FDA submissions follow in 2027, so they are intended uses rather than cleared claims for now — approved indications will be confirmed market by market as each clearance lands. Availability follows approval in each territory.
Rejuvenation, lifting and wrinkle care
Whitening
Acne and flushing care
Transdermal drug delivery support
Especificaciones
| Laser | 980 nm diode, max 10WPulse, 10–100% intensity |
| Ultrasound | 1 MHz planar, max 5WNon-focused — no focal heating by design |
| RF | 2 MHz, max 15WPulse, 10–100% intensity |
| Power Input | 100–240V, 50/60Hz80W max consumption |
| Dimensions | 1050 × 380 × 440 mmCart-type body |
| Weight | 28.5 kg |
| Protection | IP54 (body) / IP68 (footswitch) |
| Presets & Timer | 5 presets, 1–60 minTouch UI with SL/SR select |
| Safety | G-sensor in both handpieces, RF temperature sensor, interlock keyLaser and RF paths physically separated |
Configuración de Mangos

SL — Ultrasound + Laser
Intensity 10–100%, laser pulse on/off timing. Energies alternate, never overlap.

SR — Ultrasound + RF
Intensity 10–100%, RF on/off timing. RF temperature sensor on board.
¿Por qué LUMINO WAVE?
Laser and RF in one platform
Two handpieces cover a photothermal route and an RF route from a single system, so a clinic runs both without a second device and a second bed.
Coaxial, single-plane delivery
The optical exit and the ultrasound face finish at one height, so light enters at the centre of the active ultrasound field rather than beside it.
Non-focused ultrasound
A planar transducer spreads micro-vibration evenly across the contact surface. There is no focal point by design — this is not a focused-ultrasound (HIFU) device.
Three patent applications pending
Coaxial delivery structure, ultrasound tip geometry, and time-division energy control are filed separately. All three are pending applications, not granted patents.