LUMINO WAVE
型号: LSR-10
下一代融合设备
利用超声波产生的微气泡增强激光对皮肤的穿透深度,LUMINO WAVE代表了融合治疗的下一代进化。目前正在进行MFDS审批。
认证
产品图片











核心技术
超声波+激光融合
超声振动和激光照射同时进行的融合疗法。超声效应使光散射最小化,激光能更有效地到达更深层。
Time-division control — alternating, never overlapping
Wave and light fire in alternation on a millisecond time base and never overlap. One cycle repeats 50–200 times, with rest gaps after each energy. Timing is clocked on time rather than position, so the sequence holds steady while the handpiece moves.
Three energies, one platform
980nm diode laser for selective photothermal action, 1MHz non-focused planar ultrasound that spreads micro-vibration across the whole contact surface with no focal heating by design, and 2MHz RF for non-invasive deep warmth. All three run in pulse mode at 10–100% intensity.
适应症
These are the applications LUMINO WAVE is being developed for. Korea MFDS approval is in progress and CE-MDR and FDA submissions follow in 2027, so they are intended uses rather than cleared claims for now — approved indications will be confirmed market by market as each clearance lands. Availability follows approval in each territory.
Rejuvenation, lifting and wrinkle care
Whitening
Acne and flushing care
Transdermal drug delivery support
规格
| Laser | 980 nm diode, max 10WPulse, 10–100% intensity |
| Ultrasound | 1 MHz planar, max 5WNon-focused — no focal heating by design |
| RF | 2 MHz, max 15WPulse, 10–100% intensity |
| Power Input | 100–240V, 50/60Hz80W max consumption |
| Dimensions | 1050 × 380 × 440 mmCart-type body |
| Weight | 28.5 kg |
| Protection | IP54 (body) / IP68 (footswitch) |
| Presets & Timer | 5 presets, 1–60 minTouch UI with SL/SR select |
| Safety | G-sensor in both handpieces, RF temperature sensor, interlock keyLaser and RF paths physically separated |
手柄配置

SL — Ultrasound + Laser
Intensity 10–100%, laser pulse on/off timing. Energies alternate, never overlap.

SR — Ultrasound + RF
Intensity 10–100%, RF on/off timing. RF temperature sensor on board.
为什么选择LUMINO WAVE?
Laser and RF in one platform
Two handpieces cover a photothermal route and an RF route from a single system, so a clinic runs both without a second device and a second bed.
Coaxial, single-plane delivery
The optical exit and the ultrasound face finish at one height, so light enters at the centre of the active ultrasound field rather than beside it.
Non-focused ultrasound
A planar transducer spreads micro-vibration evenly across the contact surface. There is no focal point by design — this is not a focused-ultrasound (HIFU) device.
Three patent applications pending
Coaxial delivery structure, ultrasound tip geometry, and time-division energy control are filed separately. All three are pending applications, not granted patents.