LUMINO WAVE
Modèle: LSR-10
Dispositif de Convergence de Nouvelle Generation
Utilisant des microbulles induites par ultrasons pour ameliorer la profondeur de penetration du laser dans la peau, LUMINO WAVE represente la prochaine evolution de la therapie par convergence. Actuellement en cours d'approbation MFDS avec un lancement prevu au second semestre 2026.
Certifications
Images du produit











Technologies clés
Convergence Ultrasons + Laser
Therapie par convergence ou la vibration ultrasonore et l'irradiation laser se produisent simultanement. La diffusion de la lumiere est minimisee par l'effet ultrasonore, permettant au laser d'atteindre les couches profondes plus efficacement.
Time-division control — alternating, never overlapping
Wave and light fire in alternation on a millisecond time base and never overlap. One cycle repeats 50–200 times, with rest gaps after each energy. Timing is clocked on time rather than position, so the sequence holds steady while the handpiece moves.
Three energies, one platform
980nm diode laser for selective photothermal action, 1MHz non-focused planar ultrasound that spreads micro-vibration across the whole contact surface with no focal heating by design, and 2MHz RF for non-invasive deep warmth. All three run in pulse mode at 10–100% intensity.
Indications
These are the applications LUMINO WAVE is being developed for. Korea MFDS approval is in progress and CE-MDR and FDA submissions follow in 2027, so they are intended uses rather than cleared claims for now — approved indications will be confirmed market by market as each clearance lands. Availability follows approval in each territory.
Rejuvenation, lifting and wrinkle care
Whitening
Acne and flushing care
Transdermal drug delivery support
Spécifications
| Laser | 980 nm diode, max 10WPulse, 10–100% intensity |
| Ultrasound | 1 MHz planar, max 5WNon-focused — no focal heating by design |
| RF | 2 MHz, max 15WPulse, 10–100% intensity |
| Power Input | 100–240V, 50/60Hz80W max consumption |
| Dimensions | 1050 × 380 × 440 mmCart-type body |
| Weight | 28.5 kg |
| Protection | IP54 (body) / IP68 (footswitch) |
| Presets & Timer | 5 presets, 1–60 minTouch UI with SL/SR select |
| Safety | G-sensor in both handpieces, RF temperature sensor, interlock keyLaser and RF paths physically separated |
Configuration des pièces à main

SL — Ultrasound + Laser
Intensity 10–100%, laser pulse on/off timing. Energies alternate, never overlap.

SR — Ultrasound + RF
Intensity 10–100%, RF on/off timing. RF temperature sensor on board.
Pourquoi LUMINO WAVE ?
Laser and RF in one platform
Two handpieces cover a photothermal route and an RF route from a single system, so a clinic runs both without a second device and a second bed.
Coaxial, single-plane delivery
The optical exit and the ultrasound face finish at one height, so light enters at the centre of the active ultrasound field rather than beside it.
Non-focused ultrasound
A planar transducer spreads micro-vibration evenly across the contact surface. There is no focal point by design — this is not a focused-ultrasound (HIFU) device.
Three patent applications pending
Coaxial delivery structure, ultrasound tip geometry, and time-division energy control are filed separately. All three are pending applications, not granted patents.
Bénéfices cliniques
Intéressé par ce produit ?
Contactez notre équipe commerciale pour les tarifs, la planification d'une démonstration ou toute question technique.