LUMINO WAVE
Model: LSR-10
Beyond limits, with light and wave
Inside skin, laser light scatters and disperses with depth, so reaching deeper usually means raising output — and higher output means more thermal load at the surface. LUMINO WAVE answers that structurally: the laser is delivered through the centre of the ultrasound field, with the ultrasound face and the optical exit finishing on a single flat plane. Three patent applications cover the coaxial structure, the tip geometry and the time-division control that keeps the two energies from overlapping.
Certifications
Product Images
Detailed views of LUMINO WAVE and its components.
What happens next
Where LUMINO WAVE is on the way to market, and what comes after.
Pre-sales open
Partner allocations and launch planning begin with distributors in selected markets.
Regulatory programme
Korea MFDS, CE-MDR and US FDA submissions progress in parallel, market by market.
Key Technologies
Innovative technologies powering LUMINO WAVE's exceptional performance.
Coaxial delivery — light through the centre of the wave
Inside the SL handpiece a cylindrical light-guide passes through the centre of a donut-shaped planar piezo element. The ultrasound face and the optical exit finish flush at one height, so the 980nm beam enters at the exact centre of the active ultrasound field. Structural description only — no clinical performance implied.
Time-division control — alternating, never overlapping
Wave and light fire in alternation on a millisecond time base and never overlap. One cycle repeats 50–200 times, with rest gaps after each energy. Timing is clocked on time rather than position, so the sequence holds steady while the handpiece moves.
Three energies, one platform
980nm diode laser for selective photothermal action, 1MHz non-focused planar ultrasound that spreads micro-vibration across the whole contact surface with no focal heating by design, and 2MHz RF for non-invasive deep warmth. All three run in pulse mode at 10–100% intensity.
Treatment Areas & Indications
Applications LUMINO WAVE is being developed for.
These are the applications LUMINO WAVE is being developed for. Korea MFDS approval is in progress and CE-MDR and FDA submissions follow in 2027, so they are intended uses rather than cleared claims for now — approved indications will be confirmed market by market as each clearance lands. Availability follows approval in each territory.
Rejuvenation, lifting and wrinkle care
Whitening
Acne and flushing care
Transdermal drug delivery support
Specifications
| Laser | 980 nm diode, max 10W Pulse, 10–100% intensity |
| Ultrasound | 1 MHz planar, max 5W Non-focused — no focal heating by design |
| RF | 2 MHz, max 15W Pulse, 10–100% intensity |
| Power Input | 100–240V, 50/60Hz 80W max consumption |
| Dimensions | 1050 × 380 × 440 mm Cart-type body |
| Weight | 28.5 kg |
| Protection | IP54 (body) / IP68 (footswitch) |
| Presets & Timer | 5 presets, 1–60 min Touch UI with SL/SR select |
| Safety | G-sensor in both handpieces, RF temperature sensor, interlock key Laser and RF paths physically separated |
Handpiece Configuration
Specialized handpieces tailored for different anatomical areas and treatment depths.
SL — Ultrasound + Laser
Intensity 10–100%, laser pulse on/off timing. Energies alternate, never overlap.
SR — Ultrasound + RF
Intensity 10–100%, RF on/off timing. RF temperature sensor on board.
Why LUMINO WAVE?
Key differentiators that set LUMINO WAVE apart from the competition.
Laser and RF in one platform
Two handpieces cover a photothermal route and an RF route from a single system, so a clinic runs both without a second device and a second bed.
Coaxial, single-plane delivery
The optical exit and the ultrasound face finish at one height, so light enters at the centre of the active ultrasound field rather than beside it.
Non-focused ultrasound
A planar transducer spreads micro-vibration evenly across the contact surface. There is no focal point by design — this is not a focused-ultrasound (HIFU) device.
Three patent applications pending
Coaxial delivery structure, ultrasound tip geometry, and time-division energy control are filed separately. All three are pending applications, not granted patents.
Clinical Benefits
Why clinicians choose LUMINO WAVE for their practice.
Related Products
Discover other innovative aesthetic devices from BRITZMEDI.
TORR RF
Innovative Multi-Wave RF Workstation
TORR RF is a non-invasive medical device utilizing specialized Multi-Wave Radiofrequency (RF) technology to deliver thermal energy into the dermal and subcutaneous layers.
Coming Soon
ULBLANC
Multi-Frequency Ultrasound Workstation
ULBLANC is a comprehensive skincare workstation combining dual-frequency ultrasound for tightening with acoustic cavitation for transdermal drug delivery.
NEWCHAE SHOT
A Masterpiece Built on Three Pillars
NEWCHAE SHOT is a home-care beauty device integrating professional-grade medical technologies into a compact form factor with multi-channel energy delivery.
Interested in LUMINO WAVE?
Talk to our team or download the product catalog for detailed specifications.