LUMINO WAVE
Flagship Product Approval in Progress
Medical Device

LUMINO WAVE

Model: LSR-10

Beyond limits, with light and wave

Inside skin, laser light scatters and disperses with depth, so reaching deeper usually means raising output — and higher output means more thermal load at the surface. LUMINO WAVE answers that structurally: the laser is delivered through the centre of the ultrasound field, with the ultrasound face and the optical exit finishing on a single flat plane. Three patent applications cover the coaxial structure, the tip geometry and the time-division control that keeps the two energies from overlapping.

Certifications

KC Conformity Registration (R-R-bzm-LSR-10 (Apr 29, 2025) — EMC conformity under the Radio Waves Act)
EMC Type Test (KS C 9814-1/-2, tested with both handpieces)
Korea MFDS (Medical-device approval in progress — separate from KC registration)
Patents (Three applications filed (structure, tip geometry, control method))
Gallery

Product Images

Detailed views of LUMINO WAVE and its components.

LUMINO WAVE — detail view 1
LUMINO WAVE — detail view 2
LUMINO WAVE — detail view 3
LUMINO WAVE — detail view 4
LUMINO WAVE — detail view 5
LUMINO WAVE — detail view 6
LUMINO WAVE — detail view 7
LUMINO WAVE — detail view 8
LUMINO WAVE — detail view 9
LUMINO WAVE — detail view 10
LUMINO WAVE — detail view 11
Roadmap

What happens next

Where LUMINO WAVE is on the way to market, and what comes after.

Q4 2026

Pre-sales open

Partner allocations and launch planning begin with distributors in selected markets.

2027

Regulatory programme

Korea MFDS, CE-MDR and US FDA submissions progress in parallel, market by market.

Technology

Key Technologies

Innovative technologies powering LUMINO WAVE's exceptional performance.

Coaxial delivery — light through the centre of the wave

Inside the SL handpiece a cylindrical light-guide passes through the centre of a donut-shaped planar piezo element. The ultrasound face and the optical exit finish flush at one height, so the 980nm beam enters at the exact centre of the active ultrasound field. Structural description only — no clinical performance implied.

Time-division control — alternating, never overlapping

Wave and light fire in alternation on a millisecond time base and never overlap. One cycle repeats 50–200 times, with rest gaps after each energy. Timing is clocked on time rather than position, so the sequence holds steady while the handpiece moves.

Three energies, one platform

980nm diode laser for selective photothermal action, 1MHz non-focused planar ultrasound that spreads micro-vibration across the whole contact surface with no focal heating by design, and 2MHz RF for non-invasive deep warmth. All three run in pulse mode at 10–100% intensity.

Intended Applications

Treatment Areas & Indications

Applications LUMINO WAVE is being developed for.

These are the applications LUMINO WAVE is being developed for. Korea MFDS approval is in progress and CE-MDR and FDA submissions follow in 2027, so they are intended uses rather than cleared claims for now — approved indications will be confirmed market by market as each clearance lands. Availability follows approval in each territory.

Rejuvenation, lifting and wrinkle care

Whitening

Acne and flushing care

Transdermal drug delivery support

Technical Data

Specifications

Laser 980 nm diode, max 10W Pulse, 10–100% intensity
Ultrasound 1 MHz planar, max 5W Non-focused — no focal heating by design
RF 2 MHz, max 15W Pulse, 10–100% intensity
Power Input 100–240V, 50/60Hz 80W max consumption
Dimensions 1050 × 380 × 440 mm Cart-type body
Weight 28.5 kg
Protection IP54 (body) / IP68 (footswitch)
Presets & Timer 5 presets, 1–60 min Touch UI with SL/SR select
Safety G-sensor in both handpieces, RF temperature sensor, interlock key Laser and RF paths physically separated
Accessories

Handpiece Configuration

Specialized handpieces tailored for different anatomical areas and treatment depths.

SL — Ultrasound + Laser

SL — Ultrasound + Laser

Tip Size Coaxial: light-guide through donut piezo
Depth 980nm laser ≤10W · 1MHz ultrasound ≤5W

Intensity 10–100%, laser pulse on/off timing. Energies alternate, never overlap.

SR — Ultrasound + RF

SR — Ultrasound + RF

Tip Size Planar ultrasound with RF electrode
Depth 2MHz RF ≤15W · 1MHz ultrasound ≤5W

Intensity 10–100%, RF on/off timing. RF temperature sensor on board.

Why Choose

Why LUMINO WAVE?

Key differentiators that set LUMINO WAVE apart from the competition.

1

Laser and RF in one platform

Two handpieces cover a photothermal route and an RF route from a single system, so a clinic runs both without a second device and a second bed.

2

Coaxial, single-plane delivery

The optical exit and the ultrasound face finish at one height, so light enters at the centre of the active ultrasound field rather than beside it.

3

Non-focused ultrasound

A planar transducer spreads micro-vibration evenly across the contact surface. There is no focal point by design — this is not a focused-ultrasound (HIFU) device.

4

Three patent applications pending

Coaxial delivery structure, ultrasound tip geometry, and time-division energy control are filed separately. All three are pending applications, not granted patents.

Benefits

Clinical Benefits

Why clinicians choose LUMINO WAVE for their practice.

Achieves therapeutic results with lower power/energy
Minimized skin irritation and side effects
Maximized lifting and regeneration effects
Enhanced laser penetration to dermal layers

Interested in LUMINO WAVE?